The employer shall use another barrier or isolation method which prevents the migration of airborne asbestos from the regulated area as verified by perimeter area monitoring or clearance monitoring which meets the criteria set out in paragraph g 4 ii b of this section.
Osha required perimeter around roofing construction area.
When mechanical equipment is being used the warning line shall be erected not less than 6 feet 1 8 m from the roof edge which is parallel to the direction of mechanical equipment operation and not less than 10 feet 3 1 m from the roof edge which is perpendicular to the direction of mechanical equipment operation.
When selecting a perimeter security fence opt for a minimum height of six feet.
How far the d ring shifts and the harness stretches when it supports the full weight of a fallen worker including the weight of tool belts and other attached equipment or tools.
Establishing a restricted area around the perimeter of the project can also keep workers out of the danger zone where debris tools or materials may fall to the ground.
Post office box 211 concord nh 03302 0211 re.
Osha requires that this distance be no greater than 3 5 feet 29 cfr 1926 502 d 16 iv but it may be less for some pfas equipment.
The top rail must be 39 to 45 inches above the roof surface.
Will a caution tape or rope perimeter satisfy the requirement in subpart n 1926 550 a 9 for a barricade around a crane s swing radius.
Perimeter safety fence for construction almost all construction sites will require the use of temporary construction fence around the perimeter.
1926 1424 a 3 i before an employee goes to a location in the hazard area that is out of view of the operator the employee or someone instructed by the employee must ensure that the operator is informed that he she is going to that location.
The guardrail must be able to withstand 200 lbs of downward or outward force.
1926 subpart q concrete and masonry construction 1926 700 scope application and definitions applicable to this subpart.
Install warning lines no closer than 5 feet inside the roof edges and at a height of 34 to 45 inches.
Lay headers sheets of roofing or other materials no closer than 5 feet inside the edges of the roof and parallel to the roofline.
1926 703 requirements for cast in place concrete.
The area should be posted with signs that warn of the potential hazard.
March 10 2004 mr.
This is necessary to protect against public or criminal access to the site.
Touhey wso cst safety specialist contractors risk management inc.
Protecting employees in the hazard area.
Slide guards can help to keep material from sliding off the roof.